{"title":"Automatic Fire Suppression Systems","description":"\u003cp\u003eOur comprehensive product portfolio includesHFC-227ea (FM-200), FK-5-1-12 (Novec1230),Inert Gas (IG-541, IG-100, IG-55, IG-01), CO2, Direct Low Pressure (DLP), andKitchen Fire Suppression Systems. Each system is meticulously engineered to meet the highest performance requirements while minimizing environmental impact. We integrateeco-friendly clean agents, recyclable materials, and energy-efficient system designs to align with global sustainability goals.\u003c\/p\u003e","products":[{"product_id":"agnitar-200-fm200-fire-suppression-system","title":"AGNITAR 200 Fire Suppression Systems | HFC-2227ea (FM-200)","description":"\u003ch2 data-start=\"601\" data-end=\"713\"\u003e\u003cstrong data-start=\"601\" data-end=\"713\"\u003eAgnitar 200 HFC-227ea (FM-200) Fire Suppression Systems – Certified, Economic, and Efficient Protection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"715\" data-end=\"1055\"\u003e\u003cstrong\u003eAGNITAR 200\u003c\/strong\u003e delivers \u003cstrong data-start=\"736\" data-end=\"788\"\u003ecost-effective, high-performance fire protection\u003c\/strong\u003e using \u003cstrong data-start=\"795\" data-end=\"808\"\u003eHFC-227ea\u003c\/strong\u003e (also known as FM-200), a clean agent trusted worldwide for protecting critical infrastructure. With its \u003cstrong data-start=\"914\" data-end=\"932\"\u003ecompact design\u003c\/strong\u003e, \u003cstrong data-start=\"934\" data-end=\"954\"\u003efast suppression\u003c\/strong\u003e, and \u003cstrong data-start=\"960\" data-end=\"992\"\u003einternational certifications\u003c\/strong\u003e, it stands out as a smart solution for both safety and budget.\u003c\/p\u003e\n\u003ch3 data-start=\"1057\" data-end=\"1399\"\u003e\u003cstrong data-start=\"1059\" data-end=\"1083\"\u003eEconomic \u0026amp; Effective\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1057\" data-end=\"1399\"\u003eAGNITAR 200 is designed to deliver maximum protection with \u003cstrong data-start=\"1145\" data-end=\"1173\"\u003eminimum system footprint\u003c\/strong\u003e. It requires fewer cylinders compared to inert gas systems, reduces installation and maintenance costs, and uses an agent that is effective at low concentrations—making it \u003cstrong data-start=\"1346\" data-end=\"1398\"\u003ean economical choice without compromising safety\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-start=\"1401\" data-end=\"1508\"\u003e\u003cstrong data-start=\"1403\" data-end=\"1444\"\u003eCertified by Leading Global Standards\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1401\" data-end=\"1508\"\u003eEach system component meets strict international standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1511\" data-end=\"1565\"\u003e\n\u003cstrong data-start=\"1511\" data-end=\"1538\"\u003eClean Agent (HFC-227ea)\u003c\/strong\u003e: UL Listed \u0026amp; FM Approved\u003c\/li\u003e\n\u003cli data-start=\"1568\" data-end=\"1610\"\u003e\n\u003cstrong data-start=\"1568\" data-end=\"1594\"\u003eValves, Nozzles, Hoses\u003c\/strong\u003e: VdS Approved\u003c\/li\u003e\n\u003cli data-start=\"1613\" data-end=\"1644\"\u003e\n\u003cstrong data-start=\"1613\" data-end=\"1626\"\u003eCylinders\u003c\/strong\u003e: TPED Certified\u003c\/li\u003e\n\u003cli data-start=\"1613\" data-end=\"1644\"\u003e\n\u003cstrong\u003eHydraulic Calculations: \u003c\/strong\u003eVdS Approved\u003c\/li\u003e\n\u003cli data-start=\"1647\" data-end=\"1716\"\u003eFully compliant with \u003cstrong data-start=\"1668\" data-end=\"1681\"\u003eNFPA 2001\u003c\/strong\u003e, \u003cstrong data-start=\"1683\" data-end=\"1696\"\u003eISO 14520\u003c\/strong\u003e, and \u003cstrong data-start=\"1702\" data-end=\"1714\"\u003eEN 15004\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1718\" data-end=\"1758\"\u003e\u003cstrong data-start=\"1720\" data-end=\"1756\"\u003eClean, Safe \u0026amp; Equipment-Friendly\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1761\" data-end=\"1820\"\u003eNon-toxic, non-corrosive, and electrically non-conductive\u003c\/li\u003e\n\u003cli data-start=\"1823\" data-end=\"1880\"\u003eLeaves no residue – no cleanup required after discharge\u003c\/li\u003e\n\u003cli data-start=\"1883\" data-end=\"1963\"\u003eSafe for occupied spaces and ideal for use in areas with sensitive electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1965\" data-end=\"1990\"\u003e\u003cstrong data-start=\"1967\" data-end=\"1988\"\u003eProven \u0026amp; Reliable\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1993\" data-end=\"2047\"\u003eRapid fire suppression – typically within 10 seconds\u003c\/li\u003e\n\u003cli data-start=\"2050\" data-end=\"2134\"\u003eIdeal for both single-room and multi-room applications (directional valve support)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2234\" data-end=\"2269\"\u003e\u003cstrong data-start=\"2236\" data-end=\"2269\"\u003ePerfect for High-Value Assets\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2272\" data-end=\"2286\"\u003eData Centers\u003c\/li\u003e\n\u003cli data-start=\"2289\" data-end=\"2323\"\u003eElectrical Panels \u0026amp; Server Rooms\u003c\/li\u003e\n\u003cli data-start=\"2326\" data-end=\"2356\"\u003eTelecommunication Facilities\u003c\/li\u003e\n\u003cli data-start=\"2359\" data-end=\"2390\"\u003eMuseums, Libraries \u0026amp; Archives\u003c\/li\u003e\n\u003cli data-start=\"2393\" data-end=\"2434\"\u003eCleanrooms, Laboratories, Control Rooms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2436\" data-end=\"2678\"\u003e\u003cstrong data-start=\"2436\" data-end=\"2463\"\u003eWhy Choose Agnitar 200?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2436\" data-end=\"2678\"\u003eWith \u003cstrong data-start=\"2471\" data-end=\"2509\"\u003eglobally recognized certifications\u003c\/strong\u003e, \u003cstrong data-start=\"2511\" data-end=\"2536\"\u003eeconomic installation\u003c\/strong\u003e, and \u003cstrong data-start=\"2542\" data-end=\"2577\"\u003etrusted clean agent performance\u003c\/strong\u003e, Agnitar 200 is the smart choice for facilities that demand safety, reliability, and budget control.\u003c\/p\u003e","brand":"AGNITAR | Manufacturer of Fire Suppression Systems","offers":[{"title":"Default Title","offer_id":41620664418389,"sku":"200FM200","price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/9719\/3301\/files\/Agnitar_1230_system_ready_to_ship.png?v=1756230237"},{"product_id":"agnitar-novec-1230-fk5112-fire-suppression-systems","title":"AGNITAR 1230 Fire Suppression Systems | FK-5-1-12 (Novec 1230)","description":"\u003ch2 data-end=\"550\" data-start=\"324\"\u003eAGNITAR 1230 uses FK-5-1-12 (also known as Novec 1230) – a clean agent with zero ozone depletion. Safe, non-toxic, residue-free fire protection with VdS-approved components and TPED-certified cylinders.\u003c\/h2\u003e\n\u003cp data-end=\"550\" data-start=\"324\"\u003e\u003cstrong data-end=\"625\" data-start=\"584\"\u003eAGNITAR 1230 Fire Suppression Systems\u003c\/strong\u003e use \u003cstrong data-end=\"670\" data-start=\"630\"\u003eFK-5-1-12 (also known as Novec 1230)\u003c\/strong\u003e – a clean, non-toxic fire suppression agent that protects people, equipment, and the environment.\u003c\/p\u003e\n\u003cp data-end=\"975\" data-start=\"770\"\u003eThis system is engineered to rapidly extinguish fires without causing damage to electronics or leaving any residue. It is \u003cstrong data-end=\"920\" data-start=\"892\"\u003esafe for occupied spaces\u003c\/strong\u003e, \u003cstrong data-end=\"940\" data-start=\"922\"\u003enon-conductive\u003c\/strong\u003e, and \u003cstrong data-end=\"974\" data-start=\"946\"\u003eenvironmentally friendly\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"1259\" data-start=\"977\"\u003eAGNITAR 1230 Fire Suppression Systems are designed for \u003cstrong data-end=\"1037\" data-start=\"1006\"\u003etotal flooding applications\u003c\/strong\u003e, delivering the agent within \u003cstrong data-end=\"1081\" data-start=\"1067\"\u003e10 seconds\u003c\/strong\u003e to suppress fires at their earliest stage. It complies with \u003cstrong data-end=\"1180\" data-start=\"1142\"\u003eNFPA 2001, ISO 14520, and EN 15004\u003c\/strong\u003e standards, and its components carry internationally recognized certifications.\u003c\/p\u003e\n\u003ch3 data-end=\"1295\" data-start=\"1266\"\u003e\u003cstrong data-end=\"1295\" data-start=\"1266\"\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-end=\"1352\" data-start=\"1298\"\u003e\n\u003cstrong data-end=\"1313\" data-start=\"1298\"\u003eAgent Name:\u003c\/strong\u003e FK-5-1-12 (also known as Novec 1230)\u003c\/li\u003e\n\u003cli data-end=\"1407\" data-start=\"1355\"\u003e\n\u003cstrong data-end=\"1371\" data-start=\"1355\"\u003eSystem Type:\u003c\/strong\u003e Total Flooding Clean Agent System\u003c\/li\u003e\n\u003cli data-end=\"1448\" data-start=\"1410\"\u003e\n\u003cstrong data-end=\"1431\" data-start=\"1410\"\u003eWorking Pressure:\u003c\/strong\u003e 25 bar \u0026amp; 42 bar\u003c\/li\u003e\n\u003cli data-end=\"1520\" data-start=\"1451\"\u003e\n\u003cstrong data-end=\"1475\" data-start=\"1451\"\u003eCylinder Capacities:\u003c\/strong\u003e 13.4, 16L, 26L, 45L, 83L, 120L, 149L, 180L, 267L\u003c\/li\u003e\n\u003cli data-end=\"1557\" data-start=\"1523\"\u003e\n\u003cstrong data-end=\"1542\" data-start=\"1523\"\u003eDischarge Time:\u003c\/strong\u003e \u0026lt; 10 seconds\u003c\/li\u003e\n\u003cli data-end=\"1620\" data-start=\"1560\"\u003e\n\u003cstrong data-end=\"1585\" data-start=\"1560\"\u003eDesign Concentration:\u003c\/strong\u003e 4.5–6% depending on hazard class\u003c\/li\u003e\n\u003cli data-end=\"1672\" data-start=\"1623\"\u003e\n\u003cstrong data-end=\"1655\" data-start=\"1623\"\u003eOperating Temperature Range:\u003c\/strong\u003e -20°C to +55°C\u003c\/li\u003e\n\u003cli data-end=\"1739\" data-start=\"1675\"\u003e\n\u003cstrong data-end=\"1693\" data-start=\"1675\"\u003eCylinder Type:\u003c\/strong\u003e TPED certified welded or seamless cylinders\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong data-end=\"1761\" data-start=\"1742\"\u003eCertifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCylinders: \u003c\/strong\u003eTPED Approved\u003c\/li\u003e\n\u003cli data-end=\"1826\" data-start=\"1799\"\u003e\n\u003cstrong\u003eValve Group: \u003c\/strong\u003eVdS Approved\u003c\/li\u003e\n\u003cli data-end=\"1864\" data-start=\"1831\"\u003e\n\u003cstrong\u003eDischarge Nozzles: \u003c\/strong\u003eVdS Approved\u003c\/li\u003e\n\u003cli data-end=\"1899\" data-start=\"1869\"\u003e\n\u003cstrong\u003eFlexible Hoses: \u003c\/strong\u003eVdS Approved\u003c\/li\u003e\n\u003cli data-end=\"1899\" data-start=\"1869\"\u003e\n\u003cstrong\u003eHydraulic Calculations:\u003c\/strong\u003e VdS Approved\u003c\/li\u003e\n\u003cli data-end=\"1941\" data-start=\"1904\"\u003e\n\u003cstrong\u003eFK-5-1-12 (Novec 1230) Clean Agent:\u003c\/strong\u003e UL and FM Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1976\" data-start=\"1948\"\u003e\u003cstrong data-end=\"1976\" data-start=\"1948\"\u003eWhy Choose AGNITAR 1230 Fire Suppression System?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-end=\"2046\" data-start=\"1979\"\u003e\n\u003cstrong data-end=\"2007\" data-start=\"1979\"\u003eSafe for Occupied Areas:\u003c\/strong\u003e Wide safety margin with low toxicity\u003c\/li\u003e\n\u003cli data-end=\"2100\" data-start=\"2049\"\u003e\n\u003cstrong data-end=\"2064\" data-start=\"2049\"\u003eNo Residue:\u003c\/strong\u003e No cleanup needed after discharge\u003c\/li\u003e\n\u003cli data-end=\"2162\" data-start=\"2103\"\u003e\n\u003cstrong data-end=\"2122\" data-start=\"2103\"\u003eNon-Conductive:\u003c\/strong\u003e Safe for use on sensitive electronics\u003c\/li\u003e\n\u003cli data-end=\"2398\" data-start=\"2319\"\u003e\n\u003cstrong data-end=\"2350\" data-start=\"2319\"\u003eHigh Engineering Standards:\u003c\/strong\u003e Based on advanced hydraulic flow calculations\u003c\/li\u003e\n\u003cli data-end=\"2469\" data-start=\"2401\"\u003e\n\u003cstrong data-end=\"2421\" data-start=\"2401\"\u003eFully Compliant:\u003c\/strong\u003e Meets or exceeds global fire safety regulations\u003c\/li\u003e\n\u003cli data-end=\"2199\" data-start=\"2165\"\u003e\n\u003cstrong data-end=\"2197\" data-start=\"2165\"\u003eEnvironmentally Responsible:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli data-end=\"2240\" data-start=\"2204\"\u003eOzone Depletion Potential (ODP): 0\u003c\/li\u003e\n\u003cli data-end=\"2280\" data-start=\"2245\"\u003eGlobal Warming Potential (GWP): 1\u003c\/li\u003e\n\u003cli data-end=\"2316\" data-start=\"2285\"\u003eAtmospheric Lifetime: ~5 days\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2493\" data-start=\"2476\"\u003e\u003cstrong data-end=\"2493\" data-start=\"2476\"\u003eApplications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-end=\"2525\" data-start=\"2496\"\u003eServer Rooms \u0026amp; Data Centers\u003c\/li\u003e\n\u003cli data-end=\"2563\" data-start=\"2528\"\u003eElectrical Panels \u0026amp; Control Rooms\u003c\/li\u003e\n\u003cli data-end=\"2596\" data-start=\"2566\"\u003eTelecommunication Facilities\u003c\/li\u003e\n\u003cli data-end=\"2625\" data-start=\"2599\"\u003eArchive \u0026amp; Museum Storage\u003c\/li\u003e\n\u003cli data-end=\"2651\" data-start=\"2628\"\u003eMedical Imaging Rooms\u003c\/li\u003e\n\u003cli data-end=\"2682\" data-start=\"2654\"\u003eLaboratories \u0026amp; Clean Rooms\u003c\/li\u003e\n\u003cli data-end=\"2717\" data-start=\"2685\"\u003eIndustrial Automation Cabinets\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AGNITAR | Manufacturer of Fire Suppression Systems","offers":[{"title":"Default Title","offer_id":41620790968405,"sku":null,"price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/9719\/3301\/files\/Installed_System.png?v=1756230237"},{"product_id":"agnitar-co2-fire-suppression-systems","title":"AGNITAR CO2 Fire Suppression Systems | Carbon Dioxide","description":"\u003ch2 data-start=\"630\" data-end=\"921\"\u003e\u003cstrong data-start=\"630\" data-end=\"670\"\u003eAGNITAR CO2 Fire Suppression Systems offer fast, clean, and high-pressure protection. Ideal for local and total flooding systems. TPED and VdS certified. Optional weighing device for safety monitoring.\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"916\" data-start=\"585\"\u003e\u003cstrong data-end=\"625\" data-start=\"585\"\u003eAGNITAR CO2 Fire Suppression Systems\u003c\/strong\u003e deliver \u003cstrong data-end=\"682\" data-start=\"634\"\u003ehigh-pressure, fast-acting, and residue-free\u003c\/strong\u003e fire protection using Carbon Dioxide (CO2). Designed for industrial and electrical applications, this system offers \u003cstrong data-end=\"852\" data-start=\"799\"\u003eboth local application and total flooding options\u003c\/strong\u003e, and supports \u003cstrong data-end=\"892\" data-start=\"867\"\u003emulti-room protection\u003c\/strong\u003e via directional valves.\u003c\/p\u003e\n\u003cp data-end=\"1203\" data-start=\"918\"\u003eCO₂ suppresses fire by \u003cstrong data-end=\"981\" data-start=\"941\"\u003edisplacing oxygen and absorbing heat\u003c\/strong\u003e, making it an excellent solution for \u003cstrong data-end=\"1052\" data-start=\"1019\"\u003enon-occupied, high-risk areas\u003c\/strong\u003e. As a \u003cstrong data-end=\"1077\" data-start=\"1059\"\u003enon-conductive\u003c\/strong\u003e, \u003cstrong data-end=\"1096\" data-start=\"1079\"\u003enon-corrosive\u003c\/strong\u003e, and \u003cstrong data-end=\"1115\" data-start=\"1102\"\u003enon-toxic\u003c\/strong\u003e extinguishing agent, it is \u003cstrong data-end=\"1202\" data-start=\"1143\"\u003esafe for use around electronics and sensitive equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"1522\" data-start=\"1205\"\u003eAGNITAR's system also includes an optional \u003cstrong data-end=\"1267\" data-start=\"1239\"\u003eWeighing Device\u003c\/strong\u003e, which provides real-time monitoring of cylinder pressure through a spring-loaded mechanical system with built-in contact for alarm activation. This feature enhances \u003cstrong data-end=\"1471\" data-start=\"1434\"\u003esafety and maintenance efficiency\u003c\/strong\u003e, ensuring the system is always ready to discharge.\u003c\/p\u003e\n\u003ch3 data-start=\"1435\" data-end=\"1471\"\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cp data-start=\"1472\" data-end=\"1533\"\u003eAGNITAR systems use components that are globally certified:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1536\" data-end=\"1565\"\u003e\u003cstrong data-start=\"1536\" data-end=\"1563\"\u003eTPED Approved Cylinders\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1568\" data-end=\"1628\"\u003e\u003cstrong data-start=\"1568\" data-end=\"1626\"\u003eVdS Approved Valve Groups, Nozzles, and Flexible Hoses, Hydraulic Calculations\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1631\" data-end=\"1704\"\u003eDesigned in accordance with \u003cstrong data-start=\"1659\" data-end=\"1670\"\u003eNFPA 12\u003c\/strong\u003e, \u003cstrong data-start=\"1672\" data-end=\"1684\"\u003eISO 6183\u003c\/strong\u003e, and \u003cstrong data-start=\"1690\" data-end=\"1702\"\u003eEN 12094\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1707\" data-end=\"1857\"\u003eCertifications such as \u003cstrong data-start=\"1730\" data-end=\"1755\"\u003eUL, FM, VdS, and LPCB\u003c\/strong\u003e are globally recognized in system components and should be considered in all compliant installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1864\" data-end=\"1885\"\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1888\" data-end=\"1955\"\u003eHigh-pressure system allows long-distance installation\u003c\/li\u003e\n\u003cli data-start=\"1958\" data-end=\"2016\"\u003eNon-toxic and non-corrosive – safe for people-free zones\u003c\/li\u003e\n\u003cli data-start=\"2019\" data-end=\"2076\"\u003eNo residue – protects electronics and prevents downtime\u003c\/li\u003e\n\u003cli data-start=\"2079\" data-end=\"2142\"\u003eDirectional valve setups reduce costs in multi-room buildings\u003c\/li\u003e\n\u003cli data-start=\"2145\" data-end=\"2197\"\u003eSupports both total flooding and local application\u003c\/li\u003e\n\u003cli data-start=\"2200\" data-end=\"2261\"\u003eCertified system components ensure international compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2268\" data-end=\"2301\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2304\" data-end=\"2337\"\u003e\n\u003cstrong data-start=\"2304\" data-end=\"2313\"\u003eAgent\u003c\/strong\u003e: Carbon Dioxide (CO2)\u003c\/li\u003e\n\u003cli data-start=\"2340\" data-end=\"2393\"\u003e\n\u003cstrong data-start=\"2340\" data-end=\"2355\"\u003eSystem Type\u003c\/strong\u003e: Total Flooding \/ Local Application\u003c\/li\u003e\n\u003cli data-start=\"2440\" data-end=\"2486\"\u003e\n\u003cstrong data-start=\"2440\" data-end=\"2453\"\u003eActuation\u003c\/strong\u003e: Electric \/ Pneumatic \/ Manual\u003c\/li\u003e\n\u003cli data-start=\"2489\" data-end=\"2528\"\u003e\n\u003cstrong data-start=\"2489\" data-end=\"2510\"\u003eTemperature Range\u003c\/strong\u003e: -20°C to +50°C\u003c\/li\u003e\n\u003cli data-start=\"2531\" data-end=\"2587\"\u003e\n\u003cstrong data-start=\"2531\" data-end=\"2551\"\u003eCylinder Options\u003c\/strong\u003e: 67L and above (custom available)\u003c\/li\u003e\n\u003cli data-start=\"2590\" data-end=\"2630\"\u003e\n\u003cstrong data-start=\"2590\" data-end=\"2608\"\u003eCertifications\u003c\/strong\u003e: TPED, VdS, EN, ISO, NFPA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2637\" data-end=\"2663\"\u003eApplication Areas\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2666\" data-end=\"2711\"\u003eElectrical Rooms \u0026amp; Transformer Compartments\u003c\/li\u003e\n\u003cli data-start=\"2714\" data-end=\"2743\"\u003eData Centers \u0026amp; Server Rooms\u003c\/li\u003e\n\u003cli data-start=\"2746\" data-end=\"2767\"\u003eMarine Engine Rooms\u003c\/li\u003e\n\u003cli data-start=\"2770\" data-end=\"2806\"\u003ePaint Booths \u0026amp; Manufacturing Zones\u003c\/li\u003e\n\u003cli data-start=\"2809\" data-end=\"2839\"\u003eArchives, Museums, Libraries\u003c\/li\u003e\n\u003cli data-start=\"2842\" data-end=\"2876\"\u003eHazardous Material Storage Areas\u003c\/li\u003e\n\u003cli data-start=\"2879\" data-end=\"2910\"\u003eTurbine Rooms \u0026amp; Rolling Mills\u003c\/li\u003e\n\u003cli data-start=\"2913\" data-end=\"2946\"\u003eMulti-room Industrial Buildings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2953\" data-end=\"3007\"\u003eLocal Application – Targeted Fire Suppression\u003c\/h3\u003e\n\u003cp data-start=\"3008\" data-end=\"3217\"\u003e\u003cstrong data-start=\"3008\" data-end=\"3029\"\u003eAGNITAR's Local Application\u003c\/strong\u003e CO2 systems are designed to suppress fires \u003cstrong data-start=\"3073\" data-end=\"3099\"\u003eat the point of origin\u003c\/strong\u003e, without flooding the entire room. This method delivers the extinguishing agent directly to specific hazards such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"3221\" data-end=\"3237\"\u003eControl panels\u003c\/li\u003e\n\u003cli data-start=\"3240\" data-end=\"3262\"\u003eIndustrial machinery\u003c\/li\u003e\n\u003cli data-start=\"3265\" data-end=\"3286\"\u003eElectrical cabinets\u003c\/li\u003e\n\u003cli data-start=\"3289\" data-end=\"3322\"\u003ePaint lines\u003c\/li\u003e\n\u003cli data-start=\"3289\" data-end=\"3322\"\u003eCNC machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3324\" data-end=\"3709\"\u003eThis targeted approach reduces the amount of gas required and offers \u003cstrong data-start=\"3393\" data-end=\"3433\"\u003efaster suppression and less downtime\u003c\/strong\u003e, especially in facilities with \u003cstrong data-start=\"3465\" data-end=\"3497\"\u003enon-occupied machinery areas\u003c\/strong\u003e. AGNITAR's systems are designed for \u003cstrong data-start=\"3534\" data-end=\"3565\"\u003eflexible nozzle positioning\u003c\/strong\u003e and \u003cstrong data-start=\"3570\" data-end=\"3605\"\u003ecustom discharge configurations\u003c\/strong\u003e, ensuring maximum efficiency where full flooding is not necessary\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"3447\" data-start=\"3387\"\u003e\u003cstrong data-end=\"3445\" data-start=\"3393\"\u003eWhy Choose Agnitar CO₂ Fire Suppression Systems?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-end=\"3519\" data-start=\"3450\"\u003e\n\u003cstrong data-end=\"3476\" data-start=\"3452\"\u003eHigh-Pressure Design\u003c\/strong\u003e: Effective even over long pipe distances\u003c\/li\u003e\n\u003cli data-end=\"3589\" data-start=\"3522\"\u003e\n\u003cstrong data-end=\"3558\" data-start=\"3524\"\u003eEconomical Multi-Zone Solution\u003c\/strong\u003e: Supports directional valves\u003c\/li\u003e\n\u003cli data-end=\"3643\" data-start=\"3592\"\u003e\n\u003cstrong data-end=\"3618\" data-start=\"3594\"\u003eCertified Components\u003c\/strong\u003e: TPED and VdS approved\u003c\/li\u003e\n\u003cli data-end=\"3707\" data-start=\"3646\"\u003e\n\u003cstrong data-end=\"3676\" data-start=\"3648\"\u003eOptional Weighing Device\u003c\/strong\u003e: Real-time safety monitoring\u003c\/li\u003e\n\u003cli data-end=\"3764\" data-start=\"3710\"\u003e\n\u003cstrong data-end=\"3726\" data-start=\"3712\"\u003eNo Residue\u003c\/strong\u003e: Zero damage to sensitive equipment\u003c\/li\u003e\n\u003cli data-end=\"3825\" data-start=\"3767\"\u003e\n\u003cstrong data-end=\"3801\" data-start=\"3769\"\u003eNon-Conductive\u003c\/strong\u003e: Safe for electronics\u003c\/li\u003e\n\u003cli data-end=\"3891\" data-start=\"3828\"\u003e\n\u003cstrong data-end=\"3856\" data-start=\"3830\"\u003eFlexible Configuration\u003c\/strong\u003e: Local or total flooding options\u003c\/li\u003e\n\u003cli data-end=\"3960\" data-start=\"3894\"\u003e\n\u003cstrong data-end=\"3930\" data-start=\"3896\"\u003eEngineered to Global Standards\u003c\/strong\u003e: Designed per NFPA, EN, ISO\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AGNITAR | Manufacturer of Fire Suppression Systems","offers":[{"title":"Default Title","offer_id":41620584759381,"sku":"CO2","price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/9719\/3301\/files\/Agnitar_CO2_Fire_System_Weighing_Device.png?v=1754675214"},{"product_id":"agnitar-inert-fire-suppression-systems","title":"AGNITAR Inert Fire Suppression Systems | 200 \u0026 300 Bar","description":"\u003ch2 data-end=\"718\" data-start=\"618\"\u003e\u003cstrong data-end=\"718\" data-start=\"645\"\u003eAGNITAR Inert (IG-541, IG-55, IG-100, IG-01) Fire Suppression Systems | 200 \u0026amp; 300 Bar\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1078\" data-start=\"720\"\u003eAGNITAR’s Inert Gas Fire Suppression Systems are engineered for the highest level of safety and environmental performance. Designed to protect critical areas such as data centers, control rooms, museums, archives, and pharmaceutical facilities, these systems suppress fire by reducing oxygen to a safe yet non-combustible level – without leaving any residue.\u003c\/p\u003e\n\u003cp data-end=\"1105\" data-start=\"1080\"\u003eOur inert agents include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"1154\" data-start=\"1108\"\u003e\n\u003cstrong data-end=\"1118\" data-start=\"1108\"\u003eIG-541\u003c\/strong\u003e (52% Nitrogen, 40% Argon, 8% CO₂)\u003c\/li\u003e\n\u003cli data-end=\"1194\" data-start=\"1157\"\u003e\n\u003cstrong data-end=\"1166\" data-start=\"1157\"\u003eIG-55\u003c\/strong\u003e (50% Nitrogen, 50% Argon)\u003c\/li\u003e\n\u003cli data-end=\"1225\" data-start=\"1197\"\u003e\n\u003cstrong data-end=\"1207\" data-start=\"1197\"\u003eIG-100\u003c\/strong\u003e (100% Nitrogen)\u003c\/li\u003e\n\u003cli data-end=\"1250\" data-start=\"1228\"\u003e\n\u003cstrong data-end=\"1237\" data-start=\"1228\"\u003eIG-01\u003c\/strong\u003e (100% Argon)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1271\" data-start=\"1252\"\u003e\u003cstrong data-end=\"1271\" data-start=\"1252\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-end=\"1407\" data-start=\"1274\"\u003e\n\u003cp\u003e\u003cstrong data-end=\"1301\" data-start=\"1274\"\u003eHigh-Pressure Cylinders\u003c\/strong\u003e: Available in \u003cstrong data-end=\"1327\" data-start=\"1316\"\u003e200 bar\u003c\/strong\u003e and \u003cstrong data-end=\"1343\" data-start=\"1332\"\u003e300 bar\u003c\/strong\u003e options for extended pipe runs and remote cylinder placement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli data-end=\"1702\" data-start=\"1563\"\u003e\n\u003cstrong data-end=\"1590\" data-start=\"1563\"\u003eMulti-Zone Optimization\u003c\/strong\u003e: Supports \u003cstrong data-end=\"1623\" data-start=\"1601\"\u003edirectional valves\u003c\/strong\u003e for cost-effective protection of multiple rooms from a single cylinder bank.\u003c\/li\u003e\n\u003cli data-end=\"1792\" data-start=\"1705\"\u003e\n\u003cstrong data-end=\"1733\" data-start=\"1705\"\u003eFast \u0026amp; Clean Suppression\u003c\/strong\u003e: No water, no residue, no damage to sensitive equipment.\u003c\/li\u003e\n\u003cli data-end=\"1869\" data-start=\"1795\"\u003e\n\u003cstrong data-end=\"1826\" data-start=\"1795\"\u003eEnvironmentally Responsible\u003c\/strong\u003e: Zero ODP, Zero GWP, and non-conductive.\u003c\/li\u003e\n\u003cli data-end=\"1950\" data-start=\"1872\"\u003e\n\u003cstrong data-end=\"1899\" data-start=\"1872\"\u003eSafe for Occupied Areas\u003c\/strong\u003e: Maintains breathable oxygen levels above 12.5%.\u003c\/li\u003e\n\u003cli data-end=\"2040\" data-start=\"1953\"\u003e\n\u003cstrong data-end=\"1971\" data-start=\"1953\"\u003eModular System\u003c\/strong\u003e: Adaptable to any project size with single or multi-zone protection.\u003c\/li\u003e\n\u003cli data-end=\"1433\" data-start=\"1410\"\u003e\n\u003cstrong data-end=\"1430\" data-start=\"1410\"\u003eCertified Safety\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli data-end=\"1468\" data-start=\"1438\"\u003e\n\u003cstrong data-end=\"1451\" data-start=\"1438\"\u003eCylinders\u003c\/strong\u003e: TPED Approved\u003c\/li\u003e\n\u003cli data-end=\"1500\" data-start=\"1473\"\u003e\n\u003cstrong data-end=\"1483\" data-start=\"1473\"\u003eValves\u003c\/strong\u003e: VdS Certified\u003c\/li\u003e\n\u003cli data-end=\"1560\" data-start=\"1505\"\u003e\n\u003cstrong data-end=\"1543\" data-start=\"1505\"\u003eDischarge Nozzles \u0026amp; Flexible Hoses\u003c\/strong\u003e: VdS Certified\u003c\/li\u003e\n\u003cli data-end=\"1560\" data-start=\"1505\"\u003e\n\u003cstrong\u003eHydraulic Calculations:\u003c\/strong\u003e VdS Certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2317\" data-start=\"2042\"\u003e\u003cstrong data-end=\"2073\" data-start=\"2042\"\u003eInternational Standards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"2317\" data-start=\"2042\"\u003eAgnitar systems are designed in accordance with \u003cstrong\u003eEN 15004\u003c\/strong\u003e, \u003cstrong data-end=\"2135\" data-start=\"2122\"\u003eISO 14520\u003c\/strong\u003e and \u003cstrong data-end=\"2153\" data-start=\"2140\"\u003eNFPA 2001\u003c\/strong\u003e standards. Every critical system component holds at least one international approval (VdS, LPCB, UL, or FM) – ensuring global compatibility and project confidence.\u003c\/p\u003e\n\u003ch3 data-end=\"2317\" data-start=\"2042\"\u003e\u003cstrong data-end=\"2344\" data-start=\"2319\"\u003eApplication Areas:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 0cm; mso-add-space: auto; text-indent: -18.0pt; mso-list: l0 level1 lfo2;\" class=\"MsoListParagraph\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003eData Centers \u0026amp; IT Infrastructure:\u003c\/b\u003e Critical for protecting servers, networking equipment, and sensitive electronics from fire hazards.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTelecommunication Facilities\u003c\/li\u003e\n\u003cli\u003eEnergy \u0026amp; Power Generation Plants\u003c\/li\u003e\n\u003cli\u003eHealthcare \u0026amp; Pharmaceutical Facilities\u003c\/li\u003e\n\u003cli\u003eIndustrial \u0026amp; Manufacturing Plants\u003c\/li\u003e\n\u003cli\u003eOil, Gas \u0026amp; Petrochemical Industries\u003c\/li\u003e\n\u003cli\u003eMuseums, Archives \u0026amp; Cultural Heritage Sites\u003c\/li\u003e\n\u003cli\u003eEducational \u0026amp; Government Buildings\u003c\/li\u003e\n\u003cli\u003eTransportation \u0026amp; Automotive Facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; line-height: 107%; font-family: 'Aptos',sans-serif; mso-ascii-theme-font: minor-latin; mso-fareast-font-family: Aptos; mso-fareast-theme-font: minor-latin; mso-hansi-theme-font: minor-latin; mso-bidi-font-family: Arial; mso-bidi-theme-font: minor-bidi; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;\"\u003eFinancial \u0026amp; Commercial Establishments:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 11.0pt; line-height: 107%; font-family: 'Aptos',sans-serif; mso-ascii-theme-font: minor-latin; mso-fareast-font-family: Aptos; mso-fareast-theme-font: minor-latin; mso-hansi-theme-font: minor-latin; mso-bidi-font-family: Arial; mso-bidi-theme-font: minor-bidi; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;\"\u003e Prevents business disruptions in banks, shopping malls, corporate offices, and data recovery centers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-end=\"2900\" data-start=\"2557\"\u003e\u003cstrong data-end=\"2580\" data-start=\"2557\"\u003eWhy Choose AGNITAR?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"2900\" data-start=\"2557\"\u003eWith flexible cylinder sizes, high working pressures, and certified components, AGNITAR’s Inert Systems deliver both performance and peace of mind. For multi-room projects or facilities requiring long piping runs, our systems offer a more efficient and cost-effective alternative to traditional clean agent solutions.\u003c\/p\u003e","brand":"AGNITAR | Manufacturer of Fire Suppression Systems","offers":[{"title":"Default Title","offer_id":41619763429461,"sku":"INRT-1","price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/9719\/3301\/files\/Agnitar_Inert_Firmly_installed.png?v=1754599014"},{"product_id":"agnitar-cabinet-dlp-fire-suppression-systems","title":"AGNITAR Cabinet (DLP) Fire Suppression  Systems – FK-5-1-12 (Novec 1230) \u0026 HFC-227ea (FM-200)","description":"\u003cp data-start=\"398\" data-end=\"774\"\u003eAGNITAR Cabinet (DLP) Fire Suppression Systems uses HFC-227ea (FM-200) \u0026amp; FK-5-1-12 (Novec 1230) to deliver advanced, 100% mechanical fire protection for electrical cabinets, server racks, and control panels. Using a Direct Low Pressure (DLP) system with heat-sensitive detection tubing, the system instantly suppresses fires directly at the source — with no electricity, batteries, or wiring required.\u003c\/p\u003e\n\u003cp data-start=\"776\" data-end=\"914\"\u003eYou can choose between FK-5-1-12 (also known as Novec 1230) or HFC-227ea (also known as FM-200) as the suppression agent. Both agents are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"917\" data-end=\"933\"\u003eNon-conductive\u003c\/li\u003e\n\u003cli data-start=\"936\" data-end=\"950\"\u003eResidue-free\u003c\/li\u003e\n\u003cli data-start=\"953\" data-end=\"986\"\u003eSafe for use in occupied spaces\u003c\/li\u003e\n\u003cli data-start=\"989\" data-end=\"1050\"\u003eIdeal for sensitive electronics and critical infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1052\" data-end=\"1303\"\u003eAGNITAR discharges in under 10 seconds, preventing fire from spreading and minimizing downtime. The system supports an optional external pressure gauge for easy visual checks and an alarm output contact for integration with SCADA, BMS, or fire panels.\u003c\/p\u003e\n\u003cp data-start=\"1305\" data-end=\"1320\"\u003eKey Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1323\" data-end=\"1381\"\u003eDirect Low Pressure system – no indirect lines, no delay\u003c\/li\u003e\n\u003cli data-start=\"1384\" data-end=\"1445\"\u003e100% mechanical operation – works even during power outages\u003c\/li\u003e\n\u003cli data-start=\"1448\" data-end=\"1515\"\u003eClean agent options: FK-5-1-12 (Novec 1230) or HFC-227ea (FM-200)\u003c\/li\u003e\n\u003cli data-start=\"1518\" data-end=\"1571\"\u003eFast activation via heat-sensitive pneumatic tubing\u003c\/li\u003e\n\u003cli data-start=\"1574\" data-end=\"1622\"\u003eSafe for human exposure – no toxic by-products\u003c\/li\u003e\n\u003cli data-start=\"1625\" data-end=\"1690\"\u003eOptional alarm signal output and cabinet-mounted pressure gauge\u003c\/li\u003e\n\u003cli data-start=\"1693\" data-end=\"1731\"\u003eDischarge time: Less than 10 seconds\u003c\/li\u003e\n\u003cli data-start=\"1734\" data-end=\"1767\"\u003eOperating range: –20°C to +50°C\u003c\/li\u003e\n\u003cli data-start=\"1770\" data-end=\"1819\"\u003eCertified to UL \/ FM \/ CE \/ NFPA 2001 standards\u003c\/li\u003e\n\u003cli data-start=\"1822\" data-end=\"1864\"\u003eCylinder sizes: 2L, 4L, 6L, 12L\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1866\" data-end=\"1881\"\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1884\" data-end=\"1913\"\u003eElectrical control cabinets\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"1942\"\u003eData center server racks\u003c\/li\u003e\n\u003cli data-start=\"1945\" data-end=\"1977\"\u003eBattery enclosures \u0026amp; inverters\u003c\/li\u003e\n\u003cli data-start=\"1980\" data-end=\"2005\"\u003eCNC \u0026amp; automation panels\u003c\/li\u003e\n\u003cli data-start=\"2008\" data-end=\"2031\"\u003eTelecom \u0026amp; IT cabinets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2033\" data-end=\"2334\"\u003eAGNITAR Cabinet (DLP) systems are designed for fast, targeted protection in confined electrical enclosures—where traditional systems can't reach. With UL\/FM certified agents like HFC-227ea (FM-200) and FK-5-1-12 (Novec 1230), you're guaranteed maximum protection with zero residue and zero compromise.\u003c\/p\u003e\n\u003cp data-start=\"2336\" data-end=\"2414\"\u003eDownload our brochure or contact us now for a custom quote and sizing support.\u003c\/p\u003e","brand":"AGNITAR | Manufacturer of Fire Suppression Systems","offers":[{"title":"Default Title","offer_id":41616264069205,"sku":"DLP-1","price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/9719\/3301\/files\/Agnitar_Cabinet_DLP_FM200_FM-200_Novec_1230_HFC-227ea_FK-5-1-12_Suppression_System_Installation.jpg?v=1791038427"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/9719\/3301\/collections\/Agnitar_Inert_Firmly_installed.png?v=1754599485","url":"https:\/\/1uvcs0-tu.myshopify.com\/es\/collections\/frontpage.oembed","provider":"AGNITAR | Manufacturer of Fire Suppression Systems","version":"1.0","type":"link"}